PAC900S12-B2

AC ilaa DC Module Korantada HVDC-DC

PAC900S12-B2 waxay taageertaa gelinta AC ee 90 V ilaa 264 V iyo galinta HVDC ee 180 V ilaa 300V.
PSU waxay bixisaa hal wax soo saar waxayna taageertaa saddex nooc oo wax soo saar ah MV12, SV12 iyo MV6.


Linkedin
43f45020
384b0cad
754c4db4
6ec95a4a

Faahfaahinta Alaabta

Tags Product

Awoodda wax-soo-saarka ee lagu qiimeeyay waa 900 W. PSU waa mid kulul oo la isku beddeli karo, waxay barbardhigtaa hadda, waxayna taageertaa isku xirka 1+1 ama 2+2.
PSU waxay taageertaa isgaarsiinta PMBus, waxayna u dirtaa macluumaadka PSU nidaamka si loo fududeeyo la socodka iyo maamulka.

Astaamaha
94% (Vin = 230 V AC, Pout = 450 W, TA = 25°C, marawaxad la'aan)
● Dhererka x Ballaca x Dhererka: 183.0 mm x 68.0 mm x40.5 mm
● Koronto koronto: 110 V AC/220 V AC hal waji, 240 VDC
● Waxay taageertaa ilaalinta gelinta AC ee korantada yar, kororka,
qulqulka xad dhaafka ah, wareegga gaaban, iyo kororka PFC
● Waxay taageertaa ilaalinta gelinta HVDC ee korantada xad-dhaafka ah, korantada yar, iyo kororka PFC
● Waxay taageertaa ilaalinta wax soo saarka koronto-dhaafka, qulqulka, wareegga gaaban, iyo heerkulka xad-dhaafka ah
● I2C ee xakameynta, barnaamijka, iyo la socodka
● CE, UL, TUV, CCC, BSMI, BIS cfic iyo CB waa la heli karaa
● 80 Plus platinum energy fficc cfic
● IEC 60950-1, EN 60950-1, UL 60950-1, GB 4943.1, IEC 62368-1
● RoHS waafaqsan
Codsiyada: Server
PSU waxay u adkeysan kartaa koronto gelin 318 V AC ah 48 saacadood (xaalad aan shaqaynayn waa la aqbali karaa).
Hadda qulqulka qulqulaya waa inuu buuxiyaa shuruudaha ETSI EN 300 132-3.
Markaad tijaabinayso hadda ugu badnaan, hubi in korantada dekedda gelinta korantadu ay buuxisay shuruudaha iyo in wax soo saarku yahay 900 W.
Shuruudaha Naqshadeynta Wadaagga hadda
1. Waxay taageertaa 1+1 ama 2+2 hab.Wadaagista hadda jirta oo keliya qaabka MV12
2. Wadarta guud ee culayska bilowga ah ee xaaladaha hawlgalka barbar socda waa in uu ka yaraado culayska la qiimeeyay ee hal PSU ah.
3. Marka ay PSU-yadu ku shaqeeyaan 1+1 ama 2+2, haddii mid ka mid ah PSU-yada uu ku shaqeeyo qaabka MV6 iyo PSU-yada kale ay ku shaqeeyaan qaabka MV12, PSUs waa inay si sax ah u shaqeeyaan iyada oo aan ffc midba midka kale ahayn.
4. Xaaladaha halka ff PSU-yada aan la wada rakibin, calaamadaha I-MON ee labada PSUs waa in aanay ffc ku samayn hawlgalka caadiga ah ee PSU-yada marka ay si toos ah isugu xidhan yihiin.
5. Isku dheelitir la'aanta wadaagga hadda jirta oo keliya xaaladda heerkulka caadiga ah.








  • Hore:
  • Xiga: